DataStage logging was changed at release 8.1 to log job run detail records into the operational repository, (xmeta) rather than the local project level log files, (RT_LOGxxx).
In case XMETA repository logging causing problem (i.e not visible from designer), we able to change the logging method back to local project log files.


RTLogging ---> Log will saved in  project level log files which is UV binary files
ORLogging --->  Log will saved in XMETA DB

Here are the steps:

1) Log into DS machine
2) Go to /opt/IBM/InformationServer/Server/Projects/
3) Choose you project directory
4) Edit DSParams file
5) Look for RTLogging and ORLogging entries

RTLogging=0
ORLogging=1

 6) Change it to

RTLogging=1
ORLogging=0

The logging should now go to project level log files instead of xmeta DB.
Note: We still need to rely on Director client to verbose the log information as the log files data are in binary form.