DataStage Warning - When deleting data set previous delete attempt not complete


main_program: When deleting data set /full_Path_of_dataset.ds, previous delete attempt not complete; removing /full_Path_of_dataset.ds.being_deleted in order to proceed.


Solution -

This error usually comes when a previous run of respective job got aborted and the auto cleanup process hasn't been completed properly.

Thursday, October 16, 2014

DataStage job fails with code=-14 [Timed out while waiting for an event]


DataStage job fails with code=-14 [Timed out while waiting for an event] - this generally happens when jobs are called from sequencers 

 

Solution :

Follow steps 1-3 in resolving this error.
1) DSWaitStartup - environment variable -
When multiple instances of a job are run from a sequence, and one or more of the job instances are set to reset, the sequence might report a status=99 or -14. This can occur because the controlling sequence did not give the job instances enough time to reset before polling its status. The start up time for a job reset must be increased. The environment variable DSWaitResetStartup can be used for this purpose.

(The maximum value that can be set for DSWaitResetStartup is the value of DSWaitStartup (default is 60). For example, if a value of 120 is required for DSWaitResetStartup, then ensure that DSWaitStartup is also set to a minimum of 120.)